Login   /  
中国页 Página brasileira Página española                                Facebook page  YouTube channel  Flickr images
Search
 

 Arrow Patients and Carers
    DiamondSpinal Injuries  
  Dotted line  
    DiamondStrokes  
  Dotted line  
    DiamondMultiple Sclerosis  
  Dotted line  
 Arrow Medical Professionals
    DiamondSpinal Injuries  
  Dotted line  
    DiamondStrokes  
  Dotted line  
    DiamondMultiple Sclerosis  
  Dotted line  

 

“The Bladder Control System gave my life back to me”Amanda Boxtel
 
“My bladder does not dominate my life anymore”.
Jo Wright
 
“I can’t remember when I last had a UTI” Lesley
 
"The number of infections that I have had since implanting this device can be counted on the fingers of one hand" Martin

 

Surgical Accessories

We produce and supply a number of surgical accessories for use by surgeons and clinicians during surgery.

Sterile Surgical Adhesive

Sterile Surgical Adhesive, Part No. BSC254Finetech Medical Sterile Surgical Adhesive (BSC254) is a one component, low slump, translucent silicone RTV material for bonding silicone elastomers to each other and to some synthetics and metals.  It is intended to be used during the implantation of the  Finetech-Brindley Bladder Control System.  Other applications may be found where a sterile silicone RTV adhesive is required, however, the purchaser should thoroughly test products made in part or otherwise incorporating Sterile Medical Adhesive to determine the accepatbility of the products performance in a specific application.

Sterile Medical Adhesive is supplied in a sterile 8 gram tube, in a double peel pouch and is intended for single use only.

Surgical Stimulator

Surgical Stimulator, Model BSD260The Surgical Stimulator (BSD260) is a battery operated device, used to generate stimulating currents that will be delivered to the nerve tissue through the Intradural or the Extradural Surgical Probes.  It is supplied non-sterile and is for use outside the sterile field.

 

Intradural Surgical Probe

The Intradural Surgical Probe (BSC264) is used with the Surgical Stimulator to stimulate and identify nerve roots intradurally.  The electrode end of the probe has three blunted hooks, tri-polar configuration, which the surgeon uses to gently lift the nerve to be stimulated away from surrounding nerves.  The Intradural Surgical probe is supplied sterile in a double peel pouch and is intended for single use only.

Intradural Surgical Probe, Model BSC264 

Extradural Surgical Probe

The Extradural Surgical Probe (BSC259) is used with the Surgical Stimulator to stimulate and identify nerves extradurally or peripherally.  The electrode end of the probe has two blunted hooks, bi-polar configuration.  The nerve may be stimulated by holding the back of the hooks against the nerve or carefully lifting the nerve in the hooks.  The Extradural Surgical Probe is supplied sterile in a double peel pouch and is intended for single use only.

Extradural Surgical Probe, Model BSC259

Tri-Pole Spring Test Lead

The Tri-pole Spring Test Lead (BSD242) is intended for use with a nerve stimulator, such as the BSD260 Surgical Stimulator, to provide temporary test connection during surgery.  The test lead has a tri-polar configuration, with the centre spring being the cathode and the two outer springs being the common anodes.  The extended springs are used to make temporary electrical contact.

Tripole Spring Test Lead, Model BSD242

The cable length of about 2.75 meters is provided to ensure that the plug end of the cable will reach well outside the sterile field.  The test cable terminates in a miniature three-conductor plug which mates with the Surgical Stimulator BSD260. 

The disposable test cable is provided in sterile, double pouched peel-packs and is intended for single use.
  

Mono-Pole Spring Test Lead

The Mono-Pole Spring Test Lead (BSD299) is intended for use with a nerve stimulator, such as the BSD260 Surgical Stimulator, to provide temporary test connection during surgery.  The test cable is a mono-pole configuration and it is the cathode output from the stimulator.  The extended spring is used to make temporary electrical contact.

Monopole Spring Test Lead, Model BSD299

The cable length of about 2.75 meters is provided to ensure that the plug end of the cable will reach well outside the sterile field.  The test cable terminates in a miniature three-conductor plug which mates with the Surgical Stimulator BSD260.

The disposable test cable is provided in sterile, double pouched peel-packs and is intended for single use.

 

Support

Contact us if you are interested in finding out more about these products.

 

 Print  
 Case Study
Sir Philip Craven-Bladder Control SystemSir Philip Craven-Bladder Control System - Thursday, September 23, 2010

Without the Finetech-Brindley system I would have had to work from home and Presidents should not do that.

 read more ...
Lesley - Bladder Control SystemLesley - Bladder Control System - Thursday, December 10, 2009

There is no way I would have attempted this before my implant.

 read more ...
Ken Williams - STIMuSTEP® dropped foot systemKen Williams - STIMuSTEP® dropped foot system - Monday, August 23, 2010

I can walk again!

 read more ...
Finetech-Brindley - Bladder Control System      |      STIMuSTEP ® - Dropped Foot System      |      Surgical Accessories
Copyright © 2008 Finetech Medical. All rights reserved. Website maintained by  Finetech Medical